Грунд за основа STAUF VDP 160

Very low emission dispersion-based primer

  • damp proof membrane on substrates with residual moisture
  • also as bonding agent on non-absorbent sub floors
  • fast drying
Запитване
Код: 111130 Категория: Brand: STAUF

Описание

    Application range

  • primer underneath to levelling with STAUF levelling compounds
  • primer underneath STAUF wood flooring adhesives (please mind the Technical data sheet especially „suitable primers“)
  • Adhesive primer prior to levelling on top of epoxy resin primer STAUF VEP 195
  • vapour barrier on cement screeds containing residual moisture up to 3.0 CM% without subfloor heating system

    Suitable subfloors

  • mastic asphalt screed
  • calcium sulphate (flow) floors (no moisture barrier)
  • wooden planks, wood fibre boards
  • chipboards V100 (E1), OSB boards
  • stone, ceramic, terrazzo, tiles
  • unlaminated gypsum fibre boards
  • cement floors
  • cement floors with residual moisture

    Product properties

  • suitable on subfloor heating systems
  • good wetting properties
  • good adhesion to various materials
  • adhesion promoter for installations
  • adhesion promoter for levelling compounds
  • easy to apply
  • can be diluted with water

    Suitable cleaner

  • water

    Color

  • cream

    Drying time

  • Thin-film application (first coat) as a bonding agent on non-absorbent surfaces: approx. 90 minutes, on absorbent surfaces (diluted 1:3 with water): approx. 30 minutes, first vapour-barrier coat undiluted: approx. 60 minutes at 20 °C
  • Thick layer application as damp proof membrane: minimum 15 hrs. at 20 °C
  • at least 15 hours on calcium sulphate based substrates in combination with cementitious filler compounds

    Additional instructions 1

  • When using for dust suppression on absorbent mineral surfaces, dilute 1:5 with water (quantity required is approx. 125 g/m²).
  • Quantity required: Thin-film application as a bonding agent on non-absorbent surfaces: approx. 100 g/m² when applied with a roller.
  • Quantity required: When applied as a vapour barrier using a roller: 150 g/m² per coat. The total quantity for both coats together must not be less than 300 g/m² at any point.
  • If applying levelling layers thicker than 10 mm, the use of STAUF VEP 195 with a sanded finish is preferred as a bonding primer.

    Room climate at work site

  • minimum 15 °C, maximum 75% rel. humidity, preferably max. 65%

    Transport requirements

  • frost-free

    Storage requirements

  • frost-free

    Shelf-life

  • 12 months

    Giscode

  • D1

    Available packaging

  • 10 kg plastic canister

Отзиви

Все още няма отзиви.

Бъдете първият написал отзив за “Грунд за основа STAUF VDP 160”